Friday, May 29, 2009

Thursday, May 21, 2009

High Voltage Spower Supply Test

input voltage 12 VDC; current drain 250 mA
output voltage 800V
input voltage change +- 2 V => output voltage change +-10V
load 10Mohm => 5V shift
output voltage ripple +-2V

Spark Detection Circiut Test


Upper Trace(CH1): Discharge Voltage
Lower Trace(CH2): Spark Det. Logical Signal

Upper Trace(CH1): Discharge Voltage
Lower Trace(CH2): Spark Det. Logical Signal

Log. signal delay: 1.25us

Wednesday, May 6, 2009

Medipix@ATLAS

=> Lot of important data foreseen for analyses in synergy with our balloon experiments and potential scientific satellite applications!